Bright White
Color code: BW · SMP coating
Screen HEX: #D6D1DA
Inside San Antonio city limits? Outside the city but still in Bexar County? In the San Antonio ETJ? Or building on rural Hill Country land? The permit path depends on exactly where your property is located and what you plan to build.
The first question is “Who has jurisdiction over my property?” A San Antonio mailing address does not always mean the property is inside San Antonio city limits. Being outside the city also does not automatically mean no approvals are required.
Start with the City of San Antonio Development Services Department for zoning, plan review, permits and inspections.
Start with Bexar County and identify which development, Fire Marshal, floodplain, septic, access or stormwater requirements apply.
County requirements can overlap with certain requirements of the city whose extraterritorial jurisdiction covers the property.
Your exact requirements can change based on building use, square footage, occupancy, utilities, floodplain status, site work and driveway access.
For projects within the incorporated City of San Antonio.
The City of San Antonio Development Services Department handles building permits for properties located within city limits. New construction can involve zoning or plat verification, plan review, permits, inspections and related trade approvals.
For properties in unincorporated Bexar County.
Do not assume that “outside the city” means “no permit.” Bexar County regulates certain construction in unincorporated areas, and covered projects can involve County Fire Marshal plan review, permitting and inspections.
Depending on the property and project, separate requirements may also involve floodplain, stormwater, driveway/right-of-way, septic/OSSF and other development approvals.
One of the most commonly misunderstood situations.
ETJ means Extraterritorial Jurisdiction. A property can be outside the incorporated city limits while certain development-related requirements still involve San Antonio.
Bexar County's current building-permit guidance addresses projects located in the City of San Antonio ETJ and directs applicants to verify applicable city-related requirements in addition to county requirements.
The answer depends heavily on location, use and site conditions.
A private shop on rural acreage can have a very different permit path from a warehouse, church, retail building, barndominium or public-use facility.
Not every project needs every item, but these are common categories to verify.
Do not use one county's answer for another property. The San Antonio region crosses multiple counties, municipalities and ETJs.
Unincorporated Bexar County can involve building, Fire Marshal, floodplain,
stormwater, access and septic requirements.
Bexar County Building Permits →
Comal County's Fire Marshal publishes a permit and inspection process for covered projects
in unincorporated areas.
Comal County Permit Overview →
In unincorporated Guadalupe County, covered commercial projects and regulated operations
require Fire Marshal permitting. Check septic/OSSF, floodplain and driveway approvals
separately, and ask the Fire Marshal whether a pre-development meeting is needed.
Guadalupe County Fire Marshal Permitting →
Septic & Floodplain Information →
Driveway Permits & Addressing →
Kendall County publishes development information covering development permits,
access, septic, floodplain, driveway/ROW and Fire Marshal resources.
Kendall County Development Information →
Bandera County publishes a development permit application for residential
and non-residential development.
Bandera County Development Permit →
Medina County development rules can apply to unincorporated property,
with additional considerations where a city ETJ is involved.
Medina County Official Website →
Seguin, Schertz, Cibolo, New Braunfels, Boerne, Bulverde, Fair Oaks Ranch, Helotes and other cities can have their own permitting, zoning, development and inspection processes.
Your roof choice can affect more than the look of your building. For projects subject to cool-roof requirements, the finish can affect permit review, material selection, price and scheduling.
The fraction of sunlight a surface reflects. A value of 0.65 means it reflects 65% of incoming solar energy.
How effectively a surface releases absorbed heat as thermal radiation. A shiny metal roof can reflect sunlight well but have low emittance.
An ASTM E1980 calculation combining reflectance and emittance. Higher SRI generally means a cooler surface under the same conditions. It is not a percentage or an insulation R-value.
The reviewer checks the roof against the energy rules that apply to the project. That means confirming the jurisdiction, building use, roof slope, whether the space below is cooled, and the chosen compliance method. Where roof reflectance requirements apply, product ratings help document that the specified roof meets them.
The submittal may need the exact panel finish and color, manufacturer test data or an accepted rating listing, and the required initial or aged values. The roof ordered and installed should match the approved documents; substitutions may need another review.
Local code check: September 28, 2026. San Antonio currently identifies the 2021 IECC as its energy code, with local amendments. The following summarizes the commercial roof provision in Section C402.3 for roofs directly above cooled conditioned spaces, subject to its applicability and exceptions.
| Roof slope | Requirement to verify |
|---|---|
| Low slope 2:12 or less | Table C402.3 includes a 3-year-aged SRI of at least 64, or 3-year-aged solar reflectance of at least 0.55 AND thermal emittance of at least 0.75, for covered roofs in Climate Zones 0–3. |
| Steeper slope Greater than 2:12 | The local amendment requires solar reflectance of at least 0.35 OR SRI of at least 29 for covered roofs. Confirm the accepted rating basis with the reviewer. |
A 2:12 slope rises 2 inches for every 12 inches horizontally. These are project-dependent code provisions, not one universal SRI requirement for every Texas building. Initial-value allowances, exceptions and other compliance methods must be checked under the applicable code.
Homes, barndominiums and unconditioned buildings: confirm the applicable residential or commercial path. A roof over uncooled space is treated differently under the provision above. Residential roof and radiant-barrier provisions need a separate review. Do not assume the city's rules apply to every county property.
San Antonio adopted codes · City amendments: Section 10-92 / C402.3 · CRRC code reference
Initial describes the new surface. Aged describes performance after weathering under the applicable test or rating procedure. A new-roof number cannot automatically be used where an aged rating is required. Confirm that the report documents the aging period and method the code accepts.
A finish can have an initial SRI above 64 and still lack documentation of an aged SRI of 64. Likewise, an initial SRI below a particular initial threshold does not automatically disqualify a product that meets the accepted aged requirement.
LEED columns are a separate comparison. A finish report may include LEED v4.1 screening columns. Those YES/NO entries are not a San Antonio permit decision or approval for your building.
These examples show why the exact product, finish and rating age matter. Ratings apply only to the tested finishes. Confirm the product documentation and availability with Texas Metal Buildings before ordering.
| Product / finish | Initial SRI | Aged SRI |
|---|---|---|
| Galvalume Plus, acrylic Certified report 2026-027R | 62 | 49 |
| Solar White SMP · 2023 report | 86 | 83 |
| Light Stone SMP · 2023 report | 65 | 65 |
| Charcoal SMP · 2023 report | 39 | 38 |
| Bright White SMP · January 2026 specifications | 81 | Not listed |
| Arctic White PVDF · January 2026 specifications | 83 | Not listed |
Galvalume example: report 2026-027R lists aged reflectance of 0.65, aged emittance of 0.10 and aged SRI of 49. If a project's selected path requires aged SRI ≥64, the reported 49 falls below it. The alternative reflectance/emittance pair above is also not demonstrated because the reported emittance is below 0.75. This does not mean Galvalume is prohibited on every building.
Do not assign one SRI to all Galvalume. A January 2026 product specification sheet lists Galvalume at 62 in one table and 72 in another, using different reflectance/emittance pairs. Both entries are marked as non-SMP/PVDF options. Confirm which tested product is being supplied; do not select the larger number by name alone.
Reference documents: certified report 2026-027R, January 9, 2026; finish report 2023-436R, April 10, 2023; and coating specifications dated January 2026. The January 2026 painted-color tables list initial SRI only. Texas Metal Buildings can help coordinate current documentation for the exact finish specified on your order.
Insulation, roof reflectance and air sealing are different parts of energy compliance. Adding insulation alone is not a blanket approval to disregard a roof-finish requirement. Any applicable exception or alternate compliance method should be documented by the project design professional and accepted by the reviewing authority.
Explore panel color references with Texas Metal Buildings. Each card shows its coating and available SRI data. Open a collection to compare swatches, then contact us to confirm available finishes for your building.
Use a physical sample for final selection. These swatches are screen approximations. HEX values describe the display color, not a paint formula, SRI rating or order code. Collections group reference finishes; similar color names can have different coatings and ratings. Confirm the exact color reference, panel system, gauge and coating with Texas Metal Buildings.
SMP means silicone-modified polyester. Color codes identify the finishes in this collection. Initial SRI values are from January 2026 specifications; aged values are not listed. This collection is not offered for standing-seam roof systems. Confirm the available panel and finish with Texas Metal Buildings.
Color code: BW · SMP coating
Screen HEX: #D6D1DA
Color code: DW · SMP coating
Screen HEX: #C0BAAA
Color code: FG · SMP coating
Screen HEX: #AB9FA1
Color code: SA · SMP coating
Screen HEX: #B79581
Color code: BD · SMP coating
Screen HEX: #883D34
Color code: AB · SMP coating
Screen HEX: #426274
Color code: FO · SMP coating
Screen HEX: #3B4E47
Color code: BS · SMP coating
Screen HEX: #472E26
Color code: CL · SMP coating
Screen HEX: #5E5B59
PVDF identifies the coating type. Color codes identify the finishes in this collection. SRI values are initial ratings from January 2026 specifications. Ask Texas Metal Buildings for the exact product documentation, including accepted aged data where required.
Color code: AR · PVDF coating
Screen HEX: #D9DCDC
Color code: RF · PVDF coating
Screen HEX: #CDCBD7
Color code: WW · PVDF coating
Screen HEX: #D7C7C5
Color code: RG · PVDF coating
Screen HEX: #B0B3B0
Color code: DU · PVDF coating
Screen HEX: #C2BCAC
Color code: HB · PVDF coating
Screen HEX: #AF988A
Color code: CG · PVDF coating
Screen HEX: #787376
Color code: RO · PVDF coating
Screen HEX: #33556E
Color code: CY · PVDF coating
Screen HEX: #41534F
Color code: DB · PVDF coating
Screen HEX: #504543
Color code: BT · PVDF coating
Screen HEX: #9A2531
Color code: ST · PVDF coating
Screen HEX: #635D61
Color code: BL · PVDF coating
Screen HEX: #2C2E30
This collection includes SMP finishes and Polar White in premium polyester (PPOL). Matched SRI ratings are from finish report 2023-436R, April 10, 2023. Cards marked Verify need confirmation of the exact color or coating before a rating can be assigned. Contact Texas Metal Buildings for assistance.
Premium polyester (PPOL)
Screen HEX: #D0D6D4
SMP coating
Screen HEX: #BCB79A
SMP coating
Screen HEX: #979A93
SMP coating
The SRI report names Desert Tan. Confirm the exact color match.
Screen HEX: #898265
SMP coating
The SRI report names Charcoal. Confirm the exact color match.
Screen HEX: #40403E
SMP coating
Screen HEX: #282722
SMP coating
Screen HEX: #A18766
SMP coating
Screen HEX: #26666F
SMP coating
Screen HEX: #701F24
SMP coating
Screen HEX: #0B1013
SMP coating
Screen HEX: #F8FCFD
SMP coating
The color chart and SRI report identify different coating versions. Confirm the exact coating with Texas Metal Buildings.
Screen HEX: #41272A
SMP coating
Screen HEX: #19332A
SMP coating
Screen HEX: #B79E64
SMP coating
Screen HEX: #8C1513
SMP coating
Screen HEX: #526551
SMP coating
Screen HEX: #463437
SMP coating
The newer report lists Black with different data. Confirm the product.
Screen HEX: #181916
This collection uses PVDF coatings. Matched SRI ratings are from finish report 2023-436R, April 10, 2023. Confirm current availability and specifications with Texas Metal Buildings before selecting the finish for your order.
PVDF coating
Screen HEX: #9D040E
PVDF coating
Screen HEX: #032F54
PVDF coating
Screen HEX: #342C29
PVDF coating
Screen HEX: #D0D9DE
PVDF coating
Screen HEX: #63645E
PVDF coating
Screen HEX: #E9E5CE
PVDF coating
Screen HEX: #142827
PVDF coating
Screen HEX: #98886F
PVDF coating
Screen HEX: #5B1B29
PVDF coating
Screen HEX: #FBFBF9
PVDF coating
Screen HEX: #1F1D1E
Galvalume is a metallic finish, separate from the SMP and PVDF painted collections. Its appearance varies; the swatch here is an illustration. For the specific acrylic Galvalume Plus tested in certified report 2026-027R, the reported SRI is 62 initial / 49 aged. Those values do not apply automatically to every Galvalume product. Ask Texas Metal Buildings to confirm the exact finish and supporting data.
A swatch does not establish code compliance. Use the exact coating, current test documentation and accepted rating age for your project. Reference colors and ratings were reviewed September 28, 2026. Contact Texas Metal Buildings for samples and finish information.
Send Texas Metal Buildings your project location and any roof-finish or SRI requirements from your plans or reviewer. We can help coordinate available product information and pricing. Energy calculations, architectural design and permit approval are handled separately by the appropriate project professionals and reviewing authority.
Discuss Your Roof OptionsLearn more: Cool Roof Rating Council: SRI and cool-roof FAQs · Rated Roof Products Directory
The cheapest time to discover a permitting issue is before the building is engineered, fabricated or delivered.
Determine whether the property is inside a city, on unincorporated county land and whether an ETJ applies.
Tell the jurisdiction exactly how the building will be used. A private shop and a public-use building can be treated very differently.
Ask the reviewing authority for its current building or development permit checklist.
Check setbacks, floodplain, drainage, septic, access, plat notes, easements and private restrictions.
Ask which sealed building plans, calculations and foundation documents must be submitted.
Once requirements are known, confirm the roof finish, any SRI requirement and the energy documentation, then finalize the building package around the correct use, loads and jurisdictional requirements.
Tell us where you're building, the size you need and how you plan to use it. Texas Metal Buildings can help configure a red-iron or cold-formed building package around the project.
If your project needs additional architectural or planning guidance, Mario Herrera with MH Planner is a professional architect who can provide more information about his services and help you understand next steps for your project. Texas Metal Buildings LLC remains your metal building supplier; architectural, permitting and planning services are handled separately by the appropriate professional.
